r502 low temp replacement - HVAC-Talk
2007年2月22日 · I thought HP80 run at lower discharged temperature than R502. In fact it runs at 5 degrees lower. It also gives 10% more capacity. Even though its discharge pressure is higher than R502. In fact 40 PSIG higher. Even though its suction pressure is higher than R502. In fact 5 PSIG higher So higher pressure does not mean bad at all.
R502, is it worth selling? - HVAC-Talk
2010年9月25日 · R502 ls still used. On old equipment with a small charge slightly short of refrigerant why would anyone think of converting. The cost of conversion done properly and drop in efficiency just don't make sense. Beyond ozone depletion.R12 and R502 were probably the greatest advancements in 20th century refrigeration.
Retrofiting a R-502 system to R-404a - HVAC-Talk
2010年8月28日 · The cap tube sizing is the same for R502 and R404A. Supco Capillary Tube Selection. Last edited by ...
R502 - HVAC-Talk
2015年12月20日 · Found an almost full 30lb jub of R502 in a building (former hospital) that my employer recently inherited. Was tucked behind a walk-in refer in the basement that appears to have been changed out to r404A years ago.
mineral oil in R502 system - HVAC-Talk
2004年12月2日 · Can mineral oil be used under any circumstances with R502? I recently checked a system where the compressor was definately low on oil with very little showing in the crankcase sight glass. This was a Copeland comp #EAVB-021ECAV. I beleive Copeland states that the oil level in the compressor should be at the 3/4 mark of the sight glass.
Replacement refrigerant for R502 - HVAC-Talk
2013年11月12日 · Join Date Oct 2003 Location Minnesota Posts 172 Post Likes Likes (Given) 0 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received)
Replacing R502, low temp applications - HVAC-Talk
2004年12月1日 · I am requesting info on what y'all did for replacing R502 in low temp applications. Please list the refrigerant blend you switched over to, the oil you used and and issues you discovered in the process. Thank you [/QUOTE Hi 404 is my best working methood
R502 compressor replacement, blend or change over to r404a?
2015年2月17日 · OK, for the last 20 years pretty much the only locally available r502 replacement compressors are marked for r404a. I have always just used r408a with no problems,just treat as 502,no need to even convert pressures. I have often wondered what everyone else is doing with these(no one other than me in this area ever marks the refrigerant they used).
R-502 almost 30lb tank - HVAC-Talk
2023年1月29日 · Hey folks, I got a tank of R-502. It has about 31 lbs of R-502. I am not sure what's it worth, but it seems like it's a lot.
R502 with POE oil - HVAC-Talk
2013年8月26日 · The system supposed to cool the chamber to -30C and has been doing it Ok. With the fades out of R502 , Danfoss changed the compressor with another name and filled with POE oil . This new compressor supposed to work with R404a. When the system is with this new compressor with POE oil and about 80%(from R502 amount)