Connecting rigid pvc conduit to flex pvc conduit - Electrician Talk
2016年8月19日 · Talking about gluing PVC, just finished a job where the home owner had his own trenching done, about 200ft., installed PVC Conduit in 10ft sections and glued after he installed the wire in the conduit sections. I was a bit nervous about the glue possibly damaging the wire.
PVC to non metallic liquid tight transition - Electrician Talk
2019年6月25日 · "90% of the time when Carflex (LFNC) switches over from a LFNC to a PVC or Fiberglass conduit it will terminate into a junction box. LFNC Fittings has to be used with LFNC per the NEC. It is allowed to use a LFNC Fitting with a PVC Female Fitting. The PVC fitting would solvent cement to the PVC conduit and the LFNC fitting would screw into it."
Termites eating PVC pipe and PEX tubing.. - Electrician Talk
2010年8月28日 · Formosan subterranean termites will go through thin sheets of metal, mortar, PVC pipe, electric power lines and telecommuni-cations lines to get to wood or cellulosic material. This termite will eat wood, paper, books, furniture — anything cellulosic.
transitioning from one type of conduit to another
2018年4月19日 · Changing from non-matalic to metalic raceway, yes in theory the conduit should be bonded on both ends. Then I get all the flash backs about underground PVC to a ridgid 90 and vertical with PVC. Or a PVC stubbed out of the ground or floor to EMT. Perhaps one day a fitting manufacture will make a transition coupling that has a spot to lay in the EG.
connecting rigid PVC to nonmetallic liquidtight??? - Electrician Talk
2018年10月3日 · I'm wanting to convert from rigid 1-1/4 PVC to flexible nonmetallic conduit, using a rigid pvc female adapter to a flex straight terminal (male) adapter. I believe this is compliant. I would be interested in opinions. The environment is residential, either unfinished basement or garage (or both). THX
Smurf Tube - Electrician Talk
2008年12月7日 · yeah nap , we had a good man feeding. and jeff i think you id'ed the problem EXACTLY. them slab guys ran the tube around , up and down, and put a " goose-neck at the stub up. i was told we used smurf because it was faster than PVC pipe. putting the string in and pulling the wire took 4 hrs. oh i forgot, the string was a bitch to get in too.
Bending 2" pvc - Electrician Talk
2014年4月28日 · 3) heat pipe till it can bend without kinking. This takes practice to know when it's ready 4) place pipe inside radius of prefabed 90 elbow. 5) Velcro pipe to the elbow 6) proceed to spray conduit with cold water. NEVER FAILS! AND ALL THE BENDS ARE THE SAME.. Works great on 4" PVC SCHEDULE 80
flexible nonmetallic conduit question - Electrician Talk
2007年10月6日 · Carflex is pvc. 2 types are used, the softer pvc outer covering we see with a more ridgid pvc interior. I believe the ridgid pvs is the white stuff you see when cutting a piece of carflex. It solvent welds to pvc conduit fittings nicely...The joints I …
2" Non-metallic Flex to Subpanel 15' Away - Electrician Talk
2016年7月29日 · Typical flex connectors have the same pipe thread as the flex size, 2" flex will have 2"male pipe thread. Not sure you will find any different. 2" pipe thread normally requires a 2 9/16" hole. A 1.5" KO will fit 1 1/4" pipe thread. Best of luck.
schedule 80 PVC - Electrician Talk
2024年8月31日 · Say I start with a 1" diameter spot on the pipe. If you put weight on the pipe some of the pressure goes towards bowing down the center of the pipe and making it collapse. But in doing so it's also going to bow outward pressing against the soil surrounding it. In fact the pipe will be much stronger than the same test applied sitting on a bench.