Delta Pag 18 inch brushless fan trial. - CorvetteForum
2023年2月3日 · Delta Pag fan/shroud fits is excellent. According to manufacturer, Fan draw is 26 amp @ 13vdc with Soft-Start. I can confirm I am drawing 28-30 amps and the soft start ramps up in less than 10 secs According to manufacturer, Fan rated @ 4,100 CFM
Anyone here use Delta PAG Brushless Fans & Controllers?
2022年8月18日 · John here with Delta PAG to help you understand how Delta PAG brushless fans function. To answer your question, Yes they are continuously variable speed based on temperature. We have digital temp/speed controller that you can set the exact temperature you want the fan to operate and the temp range for speed from low speed to full speed (SP1 & SP2).
ordered the new BRUSHLESS radiator fan by deltapag 2800cfm
2014年8月30日 · C3 Tech/Performance - ordered the new BRUSHLESS radiator fan by deltapag 2800cfm - Well... ordered it yesterday, waiting for it to come in today... I think my Spall fans are starting to go south.. they just don't keep my car cool... on the freeway at 65mph in 100* weather I can keep her at about 185... but as soon as...
Elec. Fan or Fans ... which is better??? - CorvetteForum
2017年5月4日 · The brushless fan picture Tom posted sure looks like a better unit compared to the Delta PAG fan. But Delta PAG has a nicer controller. At least it has a pretty display on it. I don't believe the 50% current limit claims. A brushless motor …
Delta PAG in business! - CorvetteForum - Chevrolet Corvette …
2018年5月8日 · C3 Tech/Performance - Delta PAG in business! - Alohas, Placed an order for Brushless fan and controller but no replies from them! Several attempts to contact them but no response.. Anybody have any info on them? Mahalos ,, …
Best electric fan setup for Dewitt's radiator - CorvetteForum
2019年4月23日 · Because a dual fan will cover more area of the radiator, that's why I want a dual fan. With a shroud. All of the area of the radiator around the fan that your single fan with no shroud doesn't cover is area of the radiator that isn't going to have any air flow through it when you're sitting there idling, meaning, the only part of the radiator that's going to be doing any …
Cooling fan controller - CorvetteForum - Chevrolet Corvette …
2016年12月9日 · The fan system you have is a 30102052 and this is a brushed fan. You can use a PWM fan controller on these fans, though they might be hard to find. The current draw listed is for both fans so figure about 18 to 20 amps each per fan of current draw. Normally you would control them with a 40 to 50 amp relay per fan.
Electric fan upgrade - Page 2 - Page 2 - CorvetteForum
As a result, brushless motors consume a fraction of the amps while doing the same/more work. Delta PAG's Brushless fans are flat out better because brushless motors are better The 12” fan pulls 1750 CFM, the 14” fan pulls 2100 CFM, and the 16” fan pulls 2800 CFM. AND YES, THEU MAKE CUSTOM SHROUDS FOR OUR C3 CORVETTES...
Why Electric Fans Cause So Many Overheating Problems
I bought a 10" fan from them for another car and the thing moves 2000 cfm which is very surprising for a 10" --- they even showed me a pic of it running with cfm airflow meter hooked up. They also have matching shrouds for their fans. My 10" fan was made in Taiwan but it is real high qualify having very solid plastic and multiple mounts.
Looking for electric fan(s) advice.... - CorvetteForum
2023年1月19日 · I run 1 Delta PAG brushless fan for a 650hp 427 SBC and the car is raced in the hot of summers... like 1/3 the weight 1/3 the power requirements, and 10 times the life span.... Brushed fans are now like an 8-trak ....