
Anterior centre-edge angle on sagittal CT: a comparison of ... - PubMed
The ACEA can be reliably measured on sagittal CT and significantly differs from dysplastic hips. ACEA measurements above 66° or below 34° may represent anterior over and under coverage.
Anterior center-edge angle | Radiology Reference Article - Radiopaedia.org
2021年9月16日 · It is used in assessing acetabular dysplasia and pincer type of femoroacetabular impingement. It is measured in the false profile view of the hip joint. The angle is measured between a vertical line through the center of the femoral head (line VC) and a second line from the center of the hip to the anterior-most aspect of the acetabulum (line CA).
Mean normal ACEA for left and right hips for each gender.
Mean normal ACEA for left and right hips for each gender. [...] Purpose: The anterior center-edge angle (ACEA) describes anterior acetabular coverage on false profile radiographs. Variability...
Determining anterior hip coverage in patients with hip dysplasia …
2023年3月6日 · As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT (ACEA CT) has also been used to measure anterior hip coverage.
Discrepancies in measuring acetabular coverage: revisiting the …
The lateral center edge angle (LCEA) and the anterior center edge angle (ACEA) are commonly used to assess acetabular coverage of the femoral head. There are two distinct methods found in the literature to obtain these angles, specifically, ...
Determining anterior hip coverage in patients with hip dysplasia …
2023年3月6日 · Anterior hip coverage is important for hip stability. As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT …
Anterior centre-edge angle on sagittal CT: a comparison of normal …
2018年5月17日 · The anterior centre-edge angle (ACEA) describes anterior acetabular coverage on false profile radiographs. Variability associated with pelvic tilt, radiographic projection, and identifying the true anterior edge, causes discrepancies in measuring an accurate ACEA. Computed tomography (CT) has the potential of improving the accuracy of ACEA.
Can we determine anterior hip coverage from pelvic …
Anterior hip coverage can be determined on both pelvic anteroposterior (AP) radiographs and false profile (FP) radiographs. Four parameters are commonly used to determine the anterior coverage on pelvic AP radiographs: the crossover index, crossover sign, anterior wall index (AWI), and rule of thirds.
(PDF) Anterior center-edge angle on sagittal CT: a ... - ResearchGate
2018年5月17日 · Purpose: The anterior center-edge angle (ACEA) describes anterior acetabular coverage on false profile radiographs. Variability associated with pelvic tilt, radiographic...
Role of the Anterior Center-Edge Angle on Acetabular Stress ...
2022年3月1日 · Objective: The purpose of this study is to investigate the influence of anterior center-edge angle (ACEA) on the mechanical stress distribution of the hip joint, via finite element analysis, to provide insights into the severity of the borderline development dysplasia.