Phase calculation with tacho - Mechanical Acoustics ... - Eng-Tips
2008年4月29日 · 102.4 kHz sampling, 130dB dynamic range . Upvote 0 Downvote. Apr 30, 2008 #5 GregLocock Automotive. Apr 10 ...
Possible reasons for VFD line reactor failure? - Eng-Tips
2002年5月29日 · It sounds like a core heating thing. To be able to judge if that is the case, one needs to look for capacitors (or long cables) to resonate with. Reactor/capacitor combinations often have a tendency to ring somewhere between 5 and 20 kHz and that is an extremely effective frequency when it comes to induction heating.
sharing signal and power ground - Circuit design | Eng-Tips
2005年7月18日 · I generally share the signal and power ground together for analog(and mixed circuits <1 KHz).Does this practice introduce noise in the system. The circuits many times does not work if I separate them, so I am forced to do it to make it work. Am I missing something about designing here.
Grounded vs ungrounded capacitor banks 1 - Eng-Tips
2005年7月8日 · As far as Cannons' Technology, it is simply a case of their 12.5 Khz signal being shunted to ground due to the low impedance of the caps at that frequency (which is the reason for the blocking units).
Plastic material which is permeable for IR (infra red) signals 3 - Eng …
2024年10月31日 · IR is in the THz range and ultrasonic is above about 20 kHz . Upvote 0 Downvote. May 8, 2008 #7 IRstuff
low-speed quadrature algorithm - Electrical Engineering ... - Eng-Tips
2009年11月10日 · I am using a quadrature sensor on a motor-driven piece of farm equipment that spins at a wide range of speeds under normal use (uses a hydraulic CVT). The quadrature signal may be in the low kHz range down to a complete stop or 0.5Hz. At present I am using two speed algorithms. One works great and the other not so much...
LED Lifetime vs. on/off time - Electrical Engineering general ...
2018年10月18日 · It's a non-linear device. Running with a NORMAL 50% duty cycle in the kHz doesn't reduce the temperature 50% it reduces it MORE THAN 50% because running an LED at a lower temperature causes it to have less losses. If you leave it off for 5 years you simply haven't used 5 years of its lifetime. Barring environmental issues as mentioned prior.
Uncontrollable Shaker Table Resonance - Eng-Tips
2022年7月16日 · N.B. simulations are based on a truckload of assumptions, which, if not true, will result in radically different results. The fact that the measured resonance is close to 2 kHz would suggest that it's likely from your fixture, simulation not withstanding. TTFN (ta ta for now) I can do absolutely anything. I'm an expert!
Traction Motor Brush Wear Problem - Eng-Tips
2007年2月9日 · It turns out that PWM components from VFD is present on all phases. Nothing phase-phase but about 400 V pk-pk 2.5 kHz common mode voltage. I will start a new thread on that - it might be of some interest. Gunnar Englund
Accuracy of fluke meter to measure inrush current - Eng-Tips
2007年5月16日 · The early electronic meters measured the peak current and scaled it to guess what the RMS may be. Now when a motor starts there is a high inrush in the first cycle or so that varies greatly depending on the point on the wave that the switch was closed.