
Two-way Fan Coil Valve | Honeywell - Honeywell Building …
Two-way high pressure fan coil valve (VU52 and VU523) are used to control flow of hot/chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. Not for use in systems containing dissolved oxygen.
The VU52, VU53, and VU54 high pressure zone valves are used to control the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils, and convectors. IMPORTANT These valves are not for use in systems containing dissolved oxygen. VU52: 2-way, normally open. VU53: 2-way, normally closed.
2-Way Fan Coil Valve 1/2" NPT, 1.0 Cv - SupplyHouse.com
VU52 and VU53 provide 2-way, straight-through control of water. Available in normally closed (VU53) or normally open (VU52) configurations. 300 psi (2,000 kPa, PN20) operating pressure rating.
Two-way Fan Coil Valve, 1/2 in. NPT, 3.5 Cv - SupplyHouse.com
VU52 and VU53 provide 2-way, straight-through control of water. Available in normally closed (VU53) or normally open (VU52) configurations. 300 psi (2,000 kPa, PN20) operating pressure rating. Patented ball seal provides long service life, soft close off.
Valve Actuators, and VU52, VU53 and VU54 Valve Bodies, will control hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. These valves are humidity resistant and are suitable for use in condensing, non-corrosive environments. Important:These valves are not for use in
• VU52 and VU53 provide 2-way, straight-through control of water • Available in normally closed (VU53) or normally open (VU52) configurations • 300 psi (2,000 kPa, PN20) operating pressure rating
Honeywell, Inc. VU52N1035 VU52; VU53 Two-Way Fan Coil Valves …
VU52N1035 VU52N1035, Honeywell, Inc., VU52; VU53 Two-Way Fan Coil Valves VU52N1035/U Honeywell Two-way Fan Coil Valve, 1/2 in. NPT, 2.5 Cv
VU52, VU53 and VU54 valves for 2-position control of low pressure steam, or hot and chilled water with up to 50% glycol in commercial HVAC equipment such as fan coil
The VU52, VU53, and VU54 high pressure zone valves are used to control the flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils, and convectors. These valves are not for use in systems containing dissolved oxygen. VU52: 2-way, normally open. VU53: 2-way, normally closed.
Honeywell VU52S2002/U Two-Way Fan Coil Valve | PlumbersStock
Honeywell VU52S2002/U 1/2" Two-Way Fan Coil Sweat Valve. The VU52 pressure, Two-Way, Fan Coil zone valves, are used to control flow of hot or chilled water in commercial HVAC equipment such as fan coil units, terminal reheat coils and convectors. IMPORTANT: Not for use in systems containing dissolved oxygen.