Solved: UCS - Nexus - Vsan questions - Cisco Community
2012年7月4日 · 1) Configure the ports on the FI as uplink ports and connect them to the ports on the n5k and configure the n5k ports as trunk. 2) For FC, first from the UP ports you'll have to mark the ports for FC. Then configure them as FC uplink …
VxRail: High vSAN Latency and CRC Errors on Network NIC Stats
2025年2月14日 · High CRC errors are symptoms of Layer 1 issues. It could be a defective cable, SFP, or Network Interface Card (NIC). The above stats are an indication that host1, host2, and host4 were receiving CRC (inbound) from host3, and host3 may be the source of the CRC errors causing vSAN performance issues.
VMware® vSANTM is a hyper-converged, software-defined storage (SDS) platform that is fully integrated with VMware vSphere®. vSAN aggregates locally attached disks of hosts that are members of a vSphere cluster to create a distributed shared storage solution. vSAN activates the rapid provisioning of storage within VMware vCenterTM as part of ...
Cisco MDS光纤交换机最常用排错命令_fcping-CSDN博客
2024年11月12日 · Fc代表 光纤 口,sup-fc0代表带内管理接口,每个VSAN一个。 查看所有设备的plogi信息。 VSAN 1一共包含2条name server 信息。 0X750000是Cisco用于交换机带内管理; 0x7500ef是一个Clariion存储的前端端口。 文章浏览阅读614次,点赞5次,收藏10次。 Round-trip min/avg/max = 1243/1259/1283 usec – 最小延时1243u秒,平均延时1259u秒,最大延时1283u秒。 5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec - 5分钟发包统计信息。
Cisco MDS9222i光纤交换机最常用排错命令 - zlg88 - 博客园
2017年7月16日 · fcping类似于以太网的ping命令,可以使用fcping fcid检测交换机到指定端口的链路通信状态,并且可以得到链路延时信息。 示范: 4 frames sent, 4 frames received, 0 timeouts. Round-trip min/avg/max = 1243/1259/1283 usec -最小延时1243u秒,平均延时1259u秒,最大延时1283u秒。 4.检查交换机状态. show environment [clock|power|fan|temperature]命令查看交换机clock、电源、风扇、温度传感器这些模块的运行状态。 show environment后面可以接一个参 …
某医院vsan部署技术手册_vsan安装与部署-CSDN博客
2024年12月24日 · Vsan网络用于组建分布式存储,测试网络和生产网络不通,生产网络需要做聚合做双链路聚合,做lacp,交换机做聚合,但链路断开存储网络不受影响。
More than two vSAN's allowed in UCS. Is it possible?
2016年2月26日 · Total 4 vHBA's needed, basically traffic segregation. Current Setup is one FC port-channel with 4 Interface on each Fabric Interconnect, carrying 2 vSAN A & B. Now, I want to introduce 2 new VSAN C & D in the existing setup but with segregation. FI's are …
vSAN从零部署教程(最简单最快部署vSAN的办法) - VM技术库
2024年9月5日 · 我们来用最简单最快的办法来部署一套vSAN集群,这个方法就是vCenter里的 Cluster vSAN quickstart。 这个 vSAN quickstart,其实就是vCenter GUI里面部署vSAN的一个安装向导/安装精灵。 我们只需准备好3-4台ESXi主机,跟着 vSAN quickstart 的提示一步一步走,就可以完成部署一个vSAN集群. 1. 进入vCenter,将全部4台ESXi主机置于维护模式. 2. 右键点击数据中心,创建一个 vSAN 集群. 3. 选择刚新创建的集群 – 配置 – 配置 – QuickStart – 添加主机. 4. …
Configuring and Managing VSANs - Cisco
2011年6月14日 · Every instance of a VSAN runs all required protocols such as FSPF, domain manager, and zoning. Fabric-related configurations in one VSAN do not affect the associated traffic in another VSAN. Events causing traffic disruptions in one VSAN are contained within that VSAN and are not propagated to other VSANs.
Every instance of a VSAN runs all required protocols such as FSPF, domain manager, and zoning. Fabric-related configurations in one VSAN do not affect the associated traffic in another VSAN. Events causing traffic disruptions in one VSAN are contained within that VSAN and are not propagated to other VSANs.
- 某些结果已被删除