AN/PDR-75 Radiac Set: Turn-in and Computer Indicator Updates
2022年8月2日 · The AN/PDR-75A radiac set is currently being fielded to replace the AN/PDR-75. Units with AN/PDR-75 radiac sets above their requirements objective (RO) need to turn in the excess for replacement. The replacement radiac set, AN/PDR-75A, is under the same LIN. If your unit is above its RO, send the excess AN/PDR-75s to RIC BY6, Tobyhanna, PA.
FIgure 5-21. AN/PDR-75 RADIAC Set - tpub.com
AN/PDR-75 RADIAC Set. The DT-236/PDR-75, (Figure 5-22), allows radiation monitoring of. individual personnel, provides accurate readings for extended periods. of time after exposure, and is also maintenance-free and lightweight. Worn on the wrist, it contains neutron and gamma radiation-sensitive.
AN/PDR-75 RADIAC Set and DT-236/PDR-75 RADIAC Detector
AN/PDR-75 RADIAC Set and DT-236/PDR-75 RADIAC Detector. There are two new RADIAC sets which have recently been fielded. The AN/PDR-75 RADIAC Set. contains the RADIAC Computer Indicator CP-696/PDR-75 (Reader), which is used to measure the. accumulated neutron and GAMMA radiation dose absorbed by the RADIAC Detector DT-236/PDR-75
The AN/PDR-75 Radiac Setmeasures the prompt and residual gamma doses and neutron doses stored on the DT-236 indi-vidual dosimeter from 1 to 1,000 centigray (cGy). The system provides a new opera-tional capability to monitor and record the total dose exposure of individual person-nel to gamma and neutron radiation. It measures total neutron and ...
MIL-R-49293 RADIAC SET AN/PDR-75 - everyspec.com
1990年6月6日 · The AN/PDR-75 Radiac Set consists of the Computer Indicator Radiac CP-696/PDR-75 (Reader), the Carrying Case CY-8420/PDR- 75 and three power cables. MIL-R-49293 Download File - 2.26 MB Report Problem (email) Status: Active. FSC Code: 5855 - Night Vision Equipment, Emitted and Reflected Radiation. Version: 04-1991:
AN/PDR-75 Radiac Set - Federation of American Scientists
AN/PDR-75 Radiac Set The Radiac Set AN/PDR-75 will provide the capability to monitor and record the exposure of individual personnel to gamma and neutron radiation. Each individual will be issued a DT-236/PDR-75 dosimeter. This device, worn on the wrist, contains a neutron diode and a phosphate glass gamma detector.
ASSIST-QuickSearch Document Details - Defense Logistics Agency
2025年2月21日 · This performance specification covers the Radiac Set, AN/PDR-75. Status: Active: Document Date: 05-JAN-2022 ...
MIL-PRF-49293 A RADIAC SET AN/PDR-75 - everyspec.com
The AN/PDR-75 Radiac Set consists of the Computer Indicator Radiac CP-696/PDR-75 (Reader), the Carrying Case CY-8420/PDR- 75 and three power cables. The Dosimeter (DT-236/PDR-75) is used with but not a part of the Radiac Set. It measures neutrons and gammas from nuclear detonations and residual neutrons and gammas from contamination.
AN/PDR-75 RADIAC Set and DT-236/PDR-75 RADIAC Detector …
The DT-236/PDR-75 Dosimeter capabilities are: It measures from 0 to 999 cGy in any combination of neutron or GAMMA doses. It is designed to nuclear survivability requirements for Neutron and GAMMA radiation fields. and EMP. The performance data is: Range is 0 to 999 cGy
Figure 5-20. Accumulated Dose Reading - tpub.com
PART E -THE AN/PDR-75 RADIAC Set WITH DT-236/PDR-75. In order to understand the functions of the AN/PDR-75 RADIAC Set, you. must be able to describe its purpose, characteristics, principles of. operation, and total dose range. 1. Purpose. The AN/PDR-75 RADIAC Set. is used to measure the accumulated neutron.