- [PDF]
NOVA T 380 - Bayer
NOVA T 380 is an intrauterine device made of polyethylene and wound with copper wire with a silver core. The surface area of the copper is 380 mm2. The polyethylene body, shaped as a modified T is impregnated with barium sulphate. Removal threads, pigmented with iron oxide are attached to the base of the vertical arm of the T.
Comparison between Cupper T380 IUD and Multiload 375
2011年6月1日 · Comparison between Cupper T380 IUD (intrauterine device) and Multiload 375 IUD insertion in early postpartum period in regard to safety, efficacy, side effects, and complications. A prospective randomized control trial enrolled 300 recently normally delivered females (within 48 h) in El-Shatby Maternity Hospital.
Five-year clinical experiences with NOVA T®380 copper IUD
2002年11月1日 · In an open, single-group, phase III clinical trial of 5 years, the clinical performance of NOVA T®380 was investigated in three centers. The device having a higher copper surface of 380 mm 2 is a modification of NOVA T®. A total of 400 voluntary women were enrolled in the study.
A comparative trial of copper T 380 and Cu 375 IUCD - PubMed
Results: In this comparative study the effectiveness and side effects of two copper releasing IUCDs, Copper-T and Cu 375 IUCD was observed. Pelvic inflammatory disease occurred more often with Cu 375 IUCD than other group.
Safety, Efficacy, and Patient Acceptability of the Copper T-380A ...
2011年3月31日 · The ParaGard Copper T 380A intrauterine device (CuT380A) provides reversible contraception that is as effective as sterilization for up to 20 years. The CuT380A is a mainstream, first-line contraceptive option for most healthy women, including nulligravid women, as well as many women who have serious medical problems.
Long-term safety, efficacy, and patient acceptability of the ...
With a remarkably low failure rate of less than 1 per 100 women in the first year of use, the Copper T-380A is in the top tier of contraceptives in terms of efficacy. Risks of utilization include perforation and an increased risk of infection in the first 20 days following insertion.
Beim Tragen eines IUP können verstärkte Periodenblutungen, leichte Zwi- schenblutungen, Anämie, Dysmenorrhoe, Unterleibs- und Kreuzschmerzen sowie Unterleibsentzündungen auftreten.
eines IUP kann mit Symptomen wie Blutun-gen oder Schmerzen einhergehen. Allerdings kann ein Pessar auch aus dem Uterus aus-gestoßen werden, ohne dass dies von der Anwenderin bemerkt wird. Bei einer teil-weisen Ausstoßung von NOVA T 380 kann der Empfängnisschutz verringert sein. Ein verlagertes IUP ist zu entfernen und durch ein neues zu ...
Five-year clinical experiences with NOVA T®380 copper IUD
2002年12月1日 · The objective of this open randomized study was to compare the clinical performance of Nova T380 and Gyne T380 Slimline copper intrauterine devices (IUDs). Eligible for analyses were 957...
Clinical performance of the Nova T380® intrauterine device in …
Objectives The purpose of the study was to evaluate the pregnancy and complication rates of this new device, with its increased area of copper, in comparison with other published results, in the clinical setting of British general practice and family planning clinics.