Gas chromatography | Instrumentation and Control Engineering
2018年3月24日 · For the carrier gas, H2 , He, Ar, N2, and so on are used, and most gases in the measurement range from 0% to 0. 1% or more can be analyzed. Chromatography column: This column separates the gas mixture into individual components. The “boiling point” is the technique used to separate the gases.
Basics of Chromatography Operation - AutomationForum
2023年11月8日 · Gas Chromatography (GC): Uses a gaseous mobile phase and is ideal for volatile compounds. Gas-Liquid Chromatography: Uses a liquid stationary phase coated on a solid support. Gas-Solid Chromatography: Employs a solid stationary phase, such as silica or alumina. Capillary Gas Chromatography: Uses very narrow columns for improved separation ...
What is meant by the term "Variable Area Flow Meter"?
2022年12月28日 · Whereas in the case of gas, this buoyancy is negligible, and the float responds only to the velocity head. Variable area flow meters can be used as indicators, transmitters, recorders, local controllers, totalizers, and many other combinations with or without alarms.
Thermostat Working Principle - AutomationForum
2023年11月7日 · With over 24 years of dedicated experience, I am a seasoned professional specializing in the commissioning, maintenance, and installation of Electrical, Instrumentation and Control systems. My expertise extends across a spectrum of industries, including Power stations, Oil and Gas, Aluminium, Utilities, Steel and Continuous process industries.
How to Choose an Oxygen Analyzer for Your Application?
2024年2月24日 · Span Calibration Gas: Oxygen gas, commonly used for span calibration to set the upper range of measurement. Ensure high-purity calibration gasses free from contaminants that could affect accuracy. Reference Gas. Some analyzers, especially those with micro mass flow meters, may require a reference gas like nitrogen to ensure accuracy and stability.
Catalytic Type Gas Detection Sensor Principle
2023年4月27日 · The gas being detected determines the response time; the greater the gas weight or molecule dimension, the longer the response time. With T50 2 sec and T90 response to methane detection takes between 5 and 10 seconds; a minor delay happens if the sensor is shielded by a sintered filter.
Dissolved Oxygen Analyser Working Principle - AutomationForum
2023年11月15日 · The working electrode is covered with a gas-permeable membrane, usually made of Teflon, which permits oxygen to diffuse through it keeping the electrolyte inside. A voltage is applied between the working electrode and the reference electrode, causing a reduction-oxidation (redox) reaction at the working electrode. Reduction: O2 + 2H2O + 4e- → ...
Displacement Transducer and its Classification - AutomationForum
2023年8月7日 · With over 24 years of dedicated experience, I am a seasoned professional specializing in the commissioning, maintenance, and installation of Electrical, Instrumentation and Control systems. My expertise extends across a spectrum of industries, including Power stations, Oil and Gas, Aluminium, Utilities, Steel and Continuous process industries.
Zirconia Oxygen Analyzers working principle and construction
2024年4月9日 · The side in contact with the gas with higher partial oxygen pressure acts as the negative electrode. Here, oxygen molecules in the gas gain electrons and transform into oxygen ions upon interaction with the zirconia element. These oxygen ions then migrate through the zirconia element towards the positive electrode on the opposite side.
What is a loop diagram and how to interpret it?
2021年11月27日 · The loop diagram is also called a loop sheet and this diagram would have all the field devices in the process control system and all these field devices would be numbered. A loop diagram would indicate the field device installation details such as their wiring and also the junction box which would connect the field to the control system.