A CNT-PDMS wearable device for simultaneous measurement of wrist pulse ...
2020年12月1日 · In this study, a CNT-PDMS based device was developed to achieve simultaneous measurement of the ECG and wrist pulse pressure (Fig. 1 A). The device integrates a strain-sensing element (a suspended PDMS membrane embedded with CNT-PDMS strip) and voltage-sensing element (CNT-PDMS electrodes).
Optimized CNT-PDMS Flexible Composite for Attachable Health …
2020年8月13日 · The CNT-PDMS composite has been widely adopted in flexible devices due to its high elasticity, piezoresistivity, and biocompatibility. In a wide range of applications, CNT-PDMS composite sensors were used for resistive strain measurement.
CNT-PDMS foams as self-powered humidity sensors based on
2023年1月7日 · As a widely used material in TENG electrodes, polydimethylsiloxane (PDMS) shows attractive characteristics, such as electron affinity, flexibility, and facile fabrication. To achieve...
Simple and cost-effective method of highly conductive and elastic ...
2018年1月22日 · In this study, we propose a simple, fast, and cost-effective fabrication method for a homogenously hybridized CNT/polydimethylsiloxane (PDMS) composite with high conductivity, stretchability,...
Design of PDMS/CNT flexible pressure sensor based on double …
2023年9月29日 · Here, we report a design approach based on the collaboration of double structure and electrical characteristics that can improve sensor sensitivity at high pressure. The surface microstructural and internal porous structure of the dielectric layer provide a more comprehensive deformation range for the sensor from a mechanical perspective.
Dual-Sided Microstructured rGO–CNT Flexible Sensors for High ...
6 天之前 · The sensitivity of modern flexible sensors based on reduced graphene oxide (rGO), CNT and PDMS has seen significant improvements, now extending to 4.4% N –1 in the low force range (<10 N), 1.8% N –1 in the medium force range (10–30 N) and 0.19% N –1 in the high force range (30–100 N) but its thickness is ∼2 cm. In addition ...
Laser-Textured Superhydrophobic Wearable Strain Sensors of L-CNT@PDMS …
2024年6月11日 · Inspired by the self-cleaning property of the surface microstructure of lotus leaves, we have designed a superhydrophobic flexible sensor of L-CNT@PDMS by a template method and a laser direct writing technique. Single-walled carbon nanotubes (CNTs) were incorporated into poly (dimethylsiloxane) (PDMS) to prepare a CNT@PDMS elastomer.
High-performance flexible pressure sensor based on synergistic ...
2025年3月27日 · The prepared CNT/GNP-PDMS composite film was cut into a rectangle of 10 mm × 20 mm, and then the microstructure/planar structure pressure sensor based on oriented conductive network was obtained, as shown in Fig. 1 b. Specifically, firstly, the CNT/GNP-PDMS microstructured material was assembled by docking with the planar structured material.
Fabrication and Analysis of Carboxylic Acid-Functionalized SWCNT/PDMS …
4 天之前 · The cavity was framed to hold the CNT/PDMS composite [21,22]. The process is shown in Figure 2. 2.2. CNT/PDMS Composite Preparation 2.2.1. Materials. The electrodes were fabricated using SWCNT-COOHs, which were purchased from Nano Research Elements (Haryana, India) with specifications shown in Table 1. Functionalized SWCNTs were chosen for ...
Influence of Carbon nanotubes (CNT) Functionalization on CNT/PDMS ...
The functionalization of carbon nanotubes (CNT) with different functional groups influences its colloidal behavior in polydimethylsiloxane (PDMS) and enhances the interfacial interaction between the CNTs and PDMS. This paper addresses the investigation of the effect of CNT functionalization on pressure sensing behaviour of CNT-PDMS nanocomposites.