electrical - Confusion over 220 and 230 volt outlets - Home …
2019年6月18日 · 220 wasn't even the original voltage. It was 200, or to be more precise 100/100 split phase, and 500V for streetcars. It was also DC. A bump was made to 105V etc. in coordination with light bulb makers. Then another bump to 110/220/550, and then, power companies yielded to the inevitable and switched to AC.
electrical - How many amps per leg on a 220V circuit? - Home ...
2024年1月11日 · 220-240v in the U.S. is 2 legs of a single phase. The 2 legs come off the transformer and have a center tap (the neutral) each leg to neutral is 120v or 240 leg to leg. If it were part of a multi phase phase system the leg to leg value would not be the same as adding each leg to neutral voltage. –
receptacle - What types of electrical outlets are found in a typical ...
Note, also, that you can perfectly well plug a 15 amp plug into a 20 amp outlet. I have exactly that situation 3' from me--I had an electrician run an extra line, it feeds two pairs of 20 amp outlets (the cost of two pairs of 20 amp outlets vs a single pair of 15 amp outlets was only a few dollars.)
electrical - How can I switch between two 240V 30A loads? - Home ...
2024年5月9日 · From the 2017 National Electrical Code: 210.19(A)(2) Branch Circuits with More than One Receptacle. Conductors of branch circuits supplying more than one receptacle for cord-and-plug-connected portable loads shall have an ampacity of …
wire - Why is the neutral conductor sometimes undersized in AC ...
2018年1月11日 · 220.61 Feeder or Service Neutral Load. (A) Basic Calculation. The feeder or service neutral load shall be the maximum unbalance of the load determined by this article. The maximum unbalanced load shall be the maximum net calculated load between the neutral conductor and any one ungrounded conductor.
electrical - Should I use 12/2 or 12/3 to wire a 220V electric ...
2016年2月25日 · Refer to the total amps for the heater. Base the wire selection on this number. The wire size should be xx/2 WITH GROUND. Try to get wire with black and red conductors for 220 volts. If the wires are black and white the white wire MUST be pemantly marked red or black. Black and white conductors ar ok for 120 volt.
electrical - Can I use 2 black THHN wires for a 240v line? - Home ...
2020年4月13日 · The answer is yes you can run your 2 hots the same color and they can be any color except white, gray, or green. If your circuit is only 220. (240 in modern terms) you will also need a ground, the ground can be metallic conduit or if …
electrical - Can I do two 220V on a single line? - Home …
I am in the process of adding subpanel. This question is a continuation from my previous question. Can I do two 220V receptacles on a single 20A line? The equipments will be drawing max 3A and 13A...
What is the typical dishwasher/disposer electrical connection?
2013年12月12日 · About the only time you use an outlet that isn't a 5-15 or 5-20 is when you are using more than 20 Amps or need 220/240 volts. The main reason is that our cords don't have a fuse in them, to prevent people from plugging in a cord that would melt before the breaker trips.
Can I backfeed a portable generator into my house's electrical …
Stack Exchange Network. Stack Exchange network consists of 183 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers.